Skip to content

Adjust a Policy

Requirement: You must own the project

Equalize the project

  1. Navigate to the project.
  2. Click the Policies tab.
  3. In the Project Equalization section, click the toggle button on the far right to On.

Add a purpose with noise reduction

  1. Navigate to the project Overview tab.
  2. Click the Add Purposes button in the center of the page.

  3. Select the desired purpose(s) from the dropdown menu. The project must have one purpose with noise reduction for policy adjustments to function. Noise reduction is indicated by the policy adjustment amount highlighted in gray. If there is no policy adjustment shown, it is the default, none.

  4. Click Save.

  5. The purpose will be staged until a user with the GOVERNANCE or PROJECT_MANAGEMENT permission approves and activates it. If you have one of these permissions, the staging will be skipped.
  6. After the purpose has been approved, click I Agree to agree to the terms of the purpose.

    Note: All members of the project must agree to the terms of the purpose; if they decline, they will be removed from the project.

Add data sources with k-anonymization policies

  1. Navigate to the Policy Adjustment tab.
  2. Select the data source from the dropdown menu. You will receive a No Adjustments Available message if there are no columns in the data sources that are associated with adjustable policies.
  3. Select the columns from the dropdown menu.

Adjust column weights and percent null

  1. In the priority ranking window, give weight from most to least important columns. The higher the weight the more usability will be provided, while still providing de-identification through the other columns.
  2. Opt to select Keep Fields in the Clear for specific columns.
  3. After assigning the weight and ensuring that the remaining weight is zero, click the Adjust button.
  4. Check that the percent NULL is appropriate for your usability. If you are content with the percent NULL, move on to the next step; if you are not satisfied with the percent NULL, repeat the previous steps until satisfied.
  5. Click Apply after you have made the acceptable adjustments.

Keep fields in the clear

After you ensure that your data source has two columns with k-anonymization policies applied,

  1. Navigate to your project and click the Overview tab.
  2. Click Add Purposes and select a purpose with a Noise Reduction and Fields in Clear tags, or create a new purpose with Noise Reduction and Fields in Clear enabled.
  3. Click Save, and then click I Agree.
  4. Navigate to the Policy Adjustment tab.
  5. Select the data source(s) and columns from the subsequent dropdown menus.
  6. Select the Keep in the Clear checkbox next to columns to be kept in the clear.
  7. Adjust the weight for the remaining columns. The Remaining Weight must equal 0.
  8. Click Adjust and then Apply.

The values for the fields you selected will now be visible to users acting under the project.